Nederlands
Senseca HD32.3TC Datalogger
1/3
Senseca HD32.3TC Datalogger 1 Senseca HD32.3TC Datalogger 2 Senseca HD32.3TC Datalogger 3
Delivery
Fast delivery across Europe
Quality
100% original parts
Support
Technical advice available
Senseca logo Senseca

Senseca HD32.3TC Datalogger

In Stock
|
Part Number: HD32.3TC

Specifications

Brand
Senseca
Part Number
HD32.3TC
Category
Industrial Part
Availability
In Stock

Product Description

Senseca products, including Senseca HD32.3TC Datalogger, are sourced through parallel import channels and delivered to our customers worldwide with speed and reliability. Even if Senseca HD32.3TC Datalogger is not listed on our website, you are welcome to request a price quote — our team will respond promptly with a tailored offer.Measurement specificationsPROBES Sensor Measuring range ResolutionAccuracyTP3207.2 / TP3207*TP3276.2 / TP3275*HP3201.2 / HP3201*TP3204S*HP3217.2R / HP3217R*AP3203.2 / AP3203*Pt100Pt100Pt100Pt100T= Pt100RH = capacitiveNTC 10 kΩ-40…100 °C-30…120 °C4…80 °C4…80 °CT= -40…100 °C RH= 0…100%0.02…5 m/s 0…80 °C0.1 °C0.1 °C0.1 °C0.1 °C0.1 °C / 0.1 RH0.01 m/sClass AT = 1/3 DINRH = ±1.5% (0…90% RH) ±2% (90… 100% RH) @ T=15 …35°C (±1.5 + 1.5% of themeasure) % @ T=remaining range± (0.05 + 5% of the measure) m/s1/3 DIN1/3 DINClass ATemp. drift @20°C0.003% / °C0.003% / °C0.003% / °C0.003% / °C0.02% RH/°C0.06% /°CLong term stability0.1 °C / year0.1 °C / year0.1 °C / year0.1 °C / year0.1% RH/ year0.12 °C / yearResponse time T9515 minutes15 minutes15 minutes15 minutes15 minutes15 cc 96 hours @ RH = 50%, T = 23°C500 cc 15 days @ T= 40 °CTank capacity and autonomy* Probes with cable length 2 m.PROBESHP3217B4HP3217BV4PMsense-PT/RH= CMOS / Patm= piezoresistive CO2 = NDIR VOC= Metal-Oxide film (only BV4)Laser scattering principleMeasuring rangeT= -20…80 °C / RH = 0…100% Patm= 300…1250 hPa / CO2 = 0…5000 ppmVOC Index = 1…500 (dimensionless)0…1000 µg/m3 (for each pollutant)ResolutionT= 0.1 °C / RH= 0.1 %RH / Patm = 0.1 hPa CO2 = 1 ppm / VOC Index = 10.1 µg/m3AccuracyT= 0.1 °C / RH= ±2% (0…80% RH) Patm= ± 0.5 hPa @ T=25 °C CO2 = ± (50 ppm + 3% della misura)VOC Index = relative qualitative measurement<5% linearity error <3% repeatabilityTemperature driftPatm = ± 0.75 Pa/°C (0…55 °C / 700…1100 hPa) CO2 =1 ppm/°C (-20…45 °C)< 0.01 µg/m3 /°CSensorLong term stabilityResponse timeT = < 0.03 °C/yearRH = < 0.25 %RH/year Patm = < ± 1 hPa/year CO2 = 5% of the measure/5 yearsT / RH = 10 s CO2= < 120 s/ Measurements update rate 1 s

SENSECAHD32.3TCDATALOGGERSENSECA HD32.3TCHD32.3TC DATALOGGER
Price on request

Contact us for the best price and fast delivery.

Similar Products