English
Fortress Interlocks Key 2 Non TK6 & TK5 Illuminating Position Switch
1/3
Fortress Interlocks Key 2 Non TK6 & TK5 Illuminating Position Switch 1 Fortress Interlocks Key 2 Non TK6 & TK5 Illuminating Position Switch 2 Fortress Interlocks Key 2 Non TK6 & TK5 Illuminating Position Switch 3
Levering
Snelle levering in NL en BE
Kwaliteit
100% originele onderdelen
Support
Technisch advies beschikbaar
FI
Fortress Interlocks

Fortress Interlocks Key 2 Non TK6 & TK5 Illuminating Position Switch

Op voorraad
|
Artikelnummer: TK5 & TK6
Switch

Specificaties

Merk
Fortress Interlocks
Artikelnummer
TK5 & TK6
Categorie
Switch
Beschikbaarheid
Op voorraad

Productbeschrijving

Non Illuminating 2 Position Key SwitchTK5, TK6 – 2 Position Non-illuminating Selector Key Switch1 Normally Open (N/O) switch for machine control.Each switch uses 1 output pin.Range of optionsPush ButtonProtruding Push Button2 Position Selector SwitchesLatchingMomentaryKey LatchingKey MomentaryNAMETK5 & TK6 - NON-ILLUMINATING 2 POSITION KEY SWITCHPART NO.TK5, TK6RANGEtGard - Interlock switches and control devices for automation safetyIntroduction to mGard Trapped key interlocking is a tried and tested method of mechanicallysafeguarding machines and processes.Mechanical keys eliminate most of the electrical wiring associated with other types of interlocks making them cost effective to install.The Fortress mGard is suitable for use up to SIL3 (IEC 62061) and Category 4 PLe (ISO 13849-1).Why Interlocks?Interlocks are mechanical, electrical or other types of devices, the purpose of which is to prevent the operation of hazardousmachine functions under specified conditions. Interlocking can be used to help protect personnel and equipment, enforceprocesses, and improve productivity.More information on interlock devices and their use on machinery can be found in ISO 14119, Safety of machinery - Interlockingdevices associated with guards - Principles for design and selection. Further information on trapped key interlocking can befound in the technical specification ISO/TS 19837.Why Mechanical?• Mechanical interlocking can be used to control hazardous energy sources.• A key from one isolation control device can be used in an intermediate transfer (key exchange) device to release keys formultiple guards.• Personnel keys released from access locks can be used to proactively prevent unexpected start up of machinery as per ISO14118.• Mechanical systems reduce wiring and fault masking risk.Key Operated SwitchKey removed, contacts openedKey Exchange DeviceAccess LockA key exchange device allows Key trapped, the intermediate transfer of actuator removedkeys within a system2Access Lock with Personnel KeyAccess key trapped, personnel key removed, guard (door) open

NONTK5FORTRESSPOSITIONTK5 TK6 NON ILLUMINATING POSITION KEY SWITCHFORTRESS INTERLOCKS TK5 TK6 NON ILLUMINATING POSITIONFORTRESS INTERLOCKS TK5 TK6 NON ILLUMINATING POSITION KEY
Prijs op aanvraag

Neem contact met ons op voor de beste prijs en snelle levering.

Vergelijkbare Producten