English
Meggitt Accelerometer 144 202 000 105
1/15
Meggitt Accelerometer 144 202 000 105 1 Meggitt Accelerometer 144 202 000 105 2 Meggitt Accelerometer 144 202 000 105 3 Meggitt Accelerometer 144 202 000 105 4 Meggitt Accelerometer 144 202 000 105 5 Meggitt Accelerometer 144 202 000 105 6 Meggitt Accelerometer 144 202 000 105 7 Meggitt Accelerometer 144 202 000 105 8 Meggitt Accelerometer 144 202 000 105 9 Meggitt Accelerometer 144 202 000 105 10 Meggitt Accelerometer 144 202 000 105 11 Meggitt Accelerometer 144 202 000 105 12 Meggitt Accelerometer 144 202 000 105 13 Meggitt Accelerometer 144 202 000 105 14 Meggitt Accelerometer 144 202 000 105 15
Levering
Snelle levering in NL en BE
Kwaliteit
100% originele onderdelen
Support
Technisch advies beschikbaar
PM
Parker Meggitt

Meggitt Accelerometer 144 202 000 105

Op voorraad
|
Artikelnummer: 144-202-000-105
Accelerometer

Specificaties

Merk
Parker Meggitt
Artikelnummer
144-202-000-105
Categorie
Accelerometer
Beschikbaarheid
Op voorraad

Productbeschrijving

SPECIFICATIONS General Input power requirements Signal transmission Signal processing: None : 2-pin system, insulated from case, charge output : Charge converter (IPC70x signal conditioner)Operating (At 23 °C ± 5 °C, 73 °F ± 9 °F) Sensitivity (at 120 Hz with 5 g,see Calibration on page 4) Dynamic measurement range Linearity• 0.01 to 100 g (peak)• 100 to 500 g (peak) Transverse sensitivity Resonant frequency Frequency response• 0.5 to 6 000 Hz• Typical deviation at 10 kHz Internal insulation resistance Capacitance• Sensor only version• Integral cable versions: 100 pC/g ± 5 % : 0.01 to 500 g peak ::::±1 % ±2% <3% > 20 kHz nominal: ±5% (lower cutoff frequency is determined by the signal conditioner) : +15 %: 109 Ω minimum : 15 pF nom. between pin (+ or −) and case (ground).8 000 pF max. between pins (+ and −).: 15 pF nom. between pin (+ or −) and case (ground).8 000 pF max. between pins (+ and −) + 200 pF/m of integral cable.Environmental Temperature range• Continuous operation : −60 to +260 °C (−76 to +500 °F)• Short-term survival : −70 to +290 °C (−94 to +554 °F) (15 minutes maximum)Temperature sensitivity error (with respect to 23 °C, 73 °F)• −60 °C to +260 °C : ± 10 % Corrosion, humidity : AISI 316L stainless steel, hermetically weldedBase-strain sensitivity : 0.8 x 10−3 g/με Shock acceleration : < 1000 g peak (half sine, 1 ms duration) along sensitive axisCA280 piezoelectric accelerometer data sheet Document reference DS 262-096Version 7 – 25.02.2026 Page 2 of 8

MEGGITTACCELEROMETER144-202-000-105MEGGITT 144-202-000-105144-202-000-105 ACCELEROMETER
Prijs op aanvraag

Neem contact met ons op voor de beste prijs en snelle levering.

Vergelijkbare Producten