Senseca LP471LUM2 Luminance Probe
Specifications
Product Description
Luminance ProbeLP 471 UVB probe for the measure of UVB IRRADIANCE 1.0·10-3 1.000…19.999 20.00…199.99 200.0…1999.9Measuring range (W/m2):…999.9·10-3 2 -3 0.1·10 0.001 0.01 0.1 Resolution (W/m ):Spectral range:280nm…315nm (Peak 305nm...310nm)Calibration uncertainty:<5%f3 (linearity):<2%f4 (instrument reading error):±1digitf5 (fatigue):<0.5%Drift after 1 year:<2%Working temperature:0…50°CRadiometric probe for IRRADIANCE measurement, in the spectral range 280nm…315nm, peak 305nm ... 310nm,Measurement range: 1.0·10-3W/m2…2000W/m2.Combined probe LP 471 P-A with two sensors for the measure ofILLUMINANCE and UVA IRRADIANCE Illuminance Measuring range (lux):0.10…199.9 …1999.9 …19999 …199.99·103 Resolution (lux):0.01 0.1 1 0.01·103 Spectral range:in agreement with standard photopic curve V(λ) <0.05%K α (temp. coefficient) f6 (T)Calibration uncertainty:<4% f’1 (in agreement with photopic response V(λ)):<6% f2 (response according to the cosine law):<3% <1% f3 (linearity):f4 (instrument reading error):<0.5% f5 (fatigue):<0.5% Class:B Drift after 1 year:<1% Working temperature:0…50°C Reference StandardsCIE n.69 - UNI 11142 Please refer to the spectral response of the LP471PHOT probeUVA Irradiance Measuring range (μW/cm2):Resolution (μW/cm2):Spectral range:Calibration uncertainty:f2 (response according to the cosine law):f3 (linearity):f4 (instrument reading error):f5 (fatigue):Drift after 1 year:Working temperature:Typical response curve: LP 471 UVB 1 0,9Relative spectral response0,8 0,7 0,6 0,5 0,4 0,3 0,20.10…199.99 …1999.9 …19999 …199.99·103 0.01 0.1 1 0.01·103 315nm…400nm (Peak 360nm)<5% <6% <1% ±1digit <0.5% <2% 0…50°CPlease refer to the spectral response of the LP471UVA probe0,1 0 250260270280290300310320330340350λ (nm)LP 471 UVC probe for the measure of UVC IRRADIANCE 1.0·10-3 Measuring range (W/m2):1.000…19.999 20.00…199.99 200.0…1999.9 …999.9·10-3 Resolution (W/m2):0.1·10-3 0.001 0.01 0.1 220nm…280nm (Peak 260nm)Spectral range:Calibration uncertainty:<5%f3 (linearity):<1%f4 (instrument reading error):±1digitf5 (fatigue):<0.5%Drift after 1 year:Spectral range:<2%Working temperature:LP SILICON-PYRA probe for the measure of GLOBAL SOLAR RADIATION 1.0·10-3 …1.000…19.999 20.00…199.99 200.0…1999.9 Measurement range (W/m2):999.9·10-3 2 -3 0.1·10 0.001 .01 0.01 Resolution (W/m ):0…50°CRadiometric probe for IRRADIANCE measurement, in the spectral range 220nm…280nm, peak 260nm,UVC. Measurement range: 1.0·10-3W/m2…2000W/m2.400 nm … 1100 nmCalibration uncertainty:f2 (response according to the cosine law):f3 (linearity):<3%f4 (instrument reading error):±1 digitf5 (fatigue):<0.5%<3% <1%Drift after 1 year:<2%Working temperature:0…50°CTypical response curve: LP 471 UVC1.501 0,9Relative spectral response1.25Spectral irradiance Wm-2 nm-1Relative spectral response0,8 0,7 0,6 0,5 0,4 0,3 0,20.75Pyranometer LP Silicon-PYRA040.50Solar spectrum A.M. 1.5 0.250,1 0 200Pyranometer LP PYRA 02, LP PYRA 03,LP PYRA 10 1.00210220230240250λ (nm)260270280290300 0.00 2505007501000125015001750Wavelength nm20002250250027503000
Technical Documents
Price on request
Contact us for the best price and fast delivery.