Senseca GDH200-07 Manometer
Specifications
Product Description
H59.0.01.6C-038Operating Manual GDH 200-07Page 6 of 6SpecificationMeasuring Range:Max. Overpressure:Measuring medium:Accuracy:0.00 ...19.99 mbar, 0.00 ...19.99 mmHg, 0.000...1.999 PSI,resolution 0.01 mbar resolution 0.01 mmHg resolution 0.001 PSI;20.0...199.9 mbar, 20.0...150.0 mmHg, 0 ...1999 Pa,resolution 0.1 mbar;resolution 0.1 mmHg;resolution 1 Pa;Measuring range for underpressure: same as above;just switch connections -> display without neg. sign.Because of automatic offset adjustment not suitable for pressures smaller than ±0.04mbar (4Pa).Suitable instrument for such measurings: GMH3110 + GMSD 2,5 (0,001mbar or 0,1Pa resolution!)500 mbar non corrosive gases (at nominal temperature = 25°C, ±1 digit, offset adjustment)20.0 ...199.9mbar:±0.2%FS hysteresis and linearity ±0.4%FS temperature dependency 0 to 50°C0.00 ...19.99mbar:±1%FS hysteresis and linearity ±2%FS temperature dependency 0 to 50°C Pressure Connections: 2 metal pressure ports for connection to 6 x 1 mm tubes at the top of device (4mm innertube Ø) standing out approx. 11mm „+“ = higher pressure, „-“ = lower pressureMeasuring Frequency:Display:Operation Elements:Min-/Max-Value Memory:Zero Function:Scale:Ambient Conditions:Storage Temperature:Power Supply:Power Consumption:Battery Life:Battery Change Indicator:Auto-Off-Function:1 measuring per second (at ‘dyn‘-measuring integrating, for quickly changing pressures)approx. 13 mm high, 3½-digit LCD 3 keys for ON/OFF, min-/max-value display, zero settingMin and max measured value are stored The display value is set to zero per keypress, identical to an autom. zero adjustmentdigital scale correction for pressure measuring -25 to 50°C; 0 to 80% RH. (not condensing)-25 to 70°C 9V-battery (in scope of supply) approx. 250µA at standard measuring of static pressures, 3mA at ‘dyn‘-measuringStandard zinc carbon battery more than 1200 hours at standard measuring!automatically if battery is used up: "BAT" when the Auto Off Function is activated, the device switches automatically off, if keypad is not attended for a longer time (selectable 1...120min).Housing:Dimensions:Weight:EMC:impact-resistant ABS, transparent panel, front side IP65 approx. 106 x 67 x 30 mm (L x W x D) without pressure portsapprox. 135g, incl. battery The device corresponds to the essential protection ratings established in the Regulationsof the Council for the Approximation of Legislation for the member countries regardingelectromagnetic compatibility (2004/108/EC). Additional fault: <1%9 9.1Reshipment and Disposal Reshipment All devices returned to the manufacturer have to be free of any residual of measuring media and otherhazardous substances. Measuring residuals at housing or sensor may be a risk for persons orenvironmentDANGERUse an adequate transport package for reshipment, especially for fully functional devices. Pleasemake sure that the device is protected in the package by enough packing materials.9.2Disposal instructions Batteries must not be disposed in the regular domestic waste but at the designated collecting points.The device must not be disposed in the unsorted municipal waste! Send the device directly to us(sufficiently stamped), if it should be disposed. We will dispose the device appropriate andenvironmentally sound.
Technical Documents
Price on request
Contact us for the best price and fast delivery.