Rotterdam, The Netherlands | info@verkopershulp.nl Nederlands
Delivery
Fast delivery across Europe
Quality
100% original parts
Support
Technical advice available
Parker Meggitt Connector

Meggitt Vibro-Meter VibroSmart® VSA002 BNC Cable Assembly with Male BNC Connectors

In Stock
|
Part Number: 211889

Specifications

Brand
Parker Meggitt
Part Number
211889
Category
Connector
Availability
In Stock

Product Description

Cable Assembly with Male BNC ConnectorsSPECIFICATIONS Supported sensors Currently available: Compatible with a range of sensors and signal conditioners using 2-wire current transmission and 3-wire voltage transmissionDynamic input channels Number of independent channels Measurement range• Voltage (AC+DC)• Current Frequency bandwidth (−0.1 dB)• Analog high-pass filterInput impedance• Voltage• Current Accuracy• Amplitude• Phase Signal to noise ration (SNR) Common-mode voltage (CMV) range Common-mode rejection ratio (CMRR)Crosstalk attenuation: 2 ::::± 3 or ± 30 VPEAK 15 or 150 mA 0.1 Hz to 19 kHz An optional (software configurable) analog high-pass filter can beadded to the AC path to configure the high-pass cutoff frequency (−3 dB) as 0.1, 1.0 or 3.0 Hz.This filter can also be disabled to allow DC-coupling of the input.: ≥ 100 kΩ, between the differential (high and low) inputs : 202 Ω ± 3 Ω, between the differential (high and low) inputs::::::≤ 1% of input FSD (measurement bandwidth from 10 Hz to 1 kHz) ≤ 1.5 ° (measurement bandwidth from 10 Hz to 1 kHz)≥ 80 dB (measurement bandwidth from 10 Hz to 2 kHz) ±5 V > 60 dB (at 50 / 60 Hz)Typically 60 dBAuxiliary input channel – used as a tachometer input Triggering method Triggering threshold (rising edge)Voltage range: Crossing of threshold on rising edge of signal : 2/3 of peak-peak value: ± 30 VRMS / ± 42.4 VAC ( PEAK ) or 60 VDCFor Ex Zone 2 applications, the voltage range of the auxiliary input channel of a VSV301 + VSB300monitoring module and terminal base must be limited to ≤ 60 VPK-PK .Tacho range : 0.017 Hz to 426 kHz (on input) Speed / frequency measurement range : 1 to 100 000 RPM / 0.017 Hz to 1.667 kHz(after division by “number of teeth”) Minimum input voltage for reliable detection• Square-wave input signal : 0.8 VPK-PK (0.017 Hz to 10 kHz) 2.0 VPK-PK (10 kHz to 427 kHz)• Sinusoidal input signal : 20.0 VPK-PK (0.017 Hz to 0.1 Hz) 10.0 VPK-PK (0.1 Hz to 1.0 Hz)2.0 VPK-PK (1.0 Hz to 20.0 Hz) 0.8 VPK-PK (20.0 Hz to 10.0 kHz) 2.0 VPK-PK (10.0 kHz to 426.4 kHz)Input impedance• Voltage : ≥ 110 kΩ, between the differential (high and low) inputs• Current : 202 Ω ± 3 Ω, between the differential (high and low) inputsDocument reference DS 660-020-021-208A Version 9 – 28.08.2023DATA SHEET VibroSmart ® VSV301 + VSB300 monitoring module 5 / 21

BNCASSEMBLY WITHCABLE ASSEMBLYVIBROSMART® VSA002 BNCCABLE ASSEMBLY WITH MALE BNCCABLE ASSEMBLY WITH MALE BNC CONNECTORSBNC CABLE ASSEMBLY WITH MALE BNC CONNECTORS

Price on request

Contact us for the best price and fast delivery.

Similar Products