Rotterdam, Nederland | info@verkopershulp.nl English
Levering
Snelle levering in NL en BE
Kwaliteit
100% originele onderdelen
Support
Technisch advies beschikbaar
Senseca Temperature

Senseca STL50-1-1R-0-00 Safety Temperature Limiter

Op voorraad
|
Artikelnummer: STL50-1-1R-0-00

Specificaties

Merk
Senseca
Artikelnummer
STL50-1-1R-0-00
Categorie
Temperature
Beschikbaarheid
Op voorraad

Productbeschrijving

GHM Group – MartensGHM Messtechnik GmbH | Kiebitzhörn 18 | 22885 Barsbüttel | Germany Phone +49-40-670 73-0 | [email protected] | www.ghm-group.de4Technical data Auxiliary energy Supply voltage Power consumption Rated voltageTest voltageCE Conformity Environmental Conditions Environmental temperature Transport and storageconditions Relative air humidity Condensation Vibrations Approval forEN 14597: 2015EN 61508:2011 SIL2 Input Pt100Thermocouple Type J Type K Type N Type S Basic accuracy Temperature coefficientDisplay Outputs Main relay (safety-related) Pre-alarm relayAnalog outputAccuracy (analog output) Housing Material Weight Electrical connection Protection type22230 V AC ±10%, 115 V AC ±10%, 24 V AC ±15%, or 24 V DC ±15 % < 4 VA 250V AC according to EN60664-1, between input / relayoutput / supply voltage Degree of contamination 2, overvoltage category III4kV= between input/relay output/supply voltageEN 61326-1: 2013 EN 61326-2-2: 2013 -10..+55 °C -30..+60 °C < 95% not permittedUse in low-vibration environments only!Temperature control devices and temperature limiters for heat generating systemsFunctional safety of electrical/electronic/programmable electronic safety-related systemsin the range -100.0 ... 600.0 °C or -100 ... 600 °C 3-wire connection, maximum resistance 4 Ω per wireProbe current <1 mA (no independent heating) Fe-CuNi range -100.0 ... 800.0 °C or -100 ... 800 °CNiCr-Ni range -150 ... 1200 °C NiCrSi-NiSi range -150 ... 1200 °C Pt10Rh-Pt range 0 ... 1600 °CIntegrated comparison point compensation ±0.5 %, ±2 digits 0.01 %/K Graphic LCD with 128 x 64 pixelswith white backlighting Changeover contact <250 V AC <200 VA <2 A cos ≥0,7; <250 VDC <80 W <2 A,internally safeguarded with 2 A slow-burning fuse Changeover contact <250 V AC <500 VA <2 A ohmic load;<30 VDC <60 W <2 A, 0/4 … 20mA burden ≤500Ω; 0/2 … 10V burden > 500Ω, galvanically isolated,Output switches automatically (load-dependent) 0.4% TK: 0.01%/K Polyamide (PA) 6.6, UL94V-0Carrier rail mounting TS35, DIN EN 60715 approx. 450g Screw terminals 0.14 ... 2.5 mm² (AWG 26 .. 14)IP20, DIN EN 60529, BGV A3

SAFETYSENSECALIMITERSAFETY TEMPERATURETEMPERATURE LIMITERSAFETY TEMPERATURE LIMITERSENSECA STL50-1-1R-0-00 SAFETY

Prijs op aanvraag

Neem contact met ons op voor de beste prijs en snelle levering.

Vergelijkbare Producten