AST KAB-E/10kN/0,2/12-30V/4...20mA Load Cell
Specificaties
Productbeschrijving
AST products, including AST KAB-E/10kN/0,2/12-30V/4...20mA Load Cell, are sourced through parallel import channels and delivered to our customers worldwide with speed and reliability. Even if AST KAB-E/10kN/0,2/12-30V/4...20mA Load Cell is not listed on our website, you are welcome to request a price quote — our team will respond promptly with a tailored offer.Wiring Code Cable length 3m with free cable endexcitation voltage +(+EX)brownsupply voltage +(UB)brownshield signal +(SHI)black greenshield(SHI)black(+SI)excitation voltage -(-EX)yellowsignal -(-SI)whiteCompressive load is positive change of signal.signal +(OUT)greenground / signal -(0V)yellowprogramming interface(PRG)whitewith integrated amplifier (0V and PRG to be connected by the customer) With integrated amplifier(0V and PRG to be connected by the customer)Specification Accuracy Class% FnomRated force (Fnom) Maximum operating force (FG) Breaking force (FB) Lateral force limit (FQ)kN % Fnom % Fnom % Fnom0.05/ 0.1/ 0.2/ 0.5/ 1/ 2/ 5/ 10 150 > 300 100Rated characteristic value (Cnom) Relative deviation of zero signal Reference excitation voltage (Uref)Input resistance (Re) Output resistance (Ra) Insulation resistance (Ris)mV/V % VDC Ω Ω Ω2.000 ± 0.002 ≤1 10 380 ± 30 352 ± 1.5 > 5 x 109Relative linearity error (dlin) 1) Relative reversibility error (v)1) Temperature effect on zero signal (TK0)Temperature effect on characterist. value (TKC)TK output signal under load Relative creep over 30 minutes (dcr, F+E) Tolerance of output signalTolerance of zero signal% % %/10K %/10K %/10K % % %Reference temperature (Tref) Rated temperature range (BT, nom) Operating temperature range (BT, G)Storage temperature range (BT, S) Environmental protection (EN 60529)C C o C o C o oSupply voltage Input current Output signal for compression force (0...FN)Alternatively:- Voltage output (max. load: 5mA)- Current output (max. resistance) Output signal for tension or pressure force (-FN ...FN)- Voltage output0.10.05≤ 0.1 ≤ 0.1 ≤ 0.05 ≤ 0.10≤ 0.05 ≤ 0.05 ≤ 0.025 ≤ 0.05≤ 0.10≤ 0.050.21) with Integrated Amplifier 0.05/ 0.1/ 0.2/ 0.5/ 1/ 2/ 5/ 10 150 > 3001000.1 0.2 0.1 0.2 0.1 ≤1+23 -20 ... +60 -30 ... +70 -40 ... +70IP 67+23 -20 ... +60 -30 ... +70 -40 ... +70IP 67VDC mA19 ... 28 35 (at 24V)V mA0 ... 10 4 ... 20 (300 Ω)VAll data according to VDI/VDE/DKD 2638-10 ... +101) Accuracy class 0.1% on requestOrder Example Type CodeDescriptionKAB-E/1kN/0.2/24V/0 ...10VForce transducer 1kN with 0.2% accuracy and integrated amplifier Output signalSupply voltage Accuracy class Rated force E = Integrated amplifier ModelOptions TypschlüsselBezeichnungATEX-CertificateKAB-EXfor 100N, 200N, 500N, 1kN, 2kN, 5kN, 10kN. Please not ATEX data sheet!CANopen interfaceKAB-DIfor 50N bis 10kN, Please note data sheet „Force Transducer with CANopen Interface“!2
Technische Documenten
Prijs op aanvraag
Neem contact met ons op voor de beste prijs en snelle levering.