Senseca K04PU-02SG Circular Connector
Specificaties
Productbeschrijving
Product information Flow - rotor probe formConfiguration Interface ECI-3Handling and operation Operating and display elements Front:LED USB COMM SUPPLY BYPASS ● Can be used on site for:- parameter modification- firmware update- adjustment of inputs and outputs ● Can be connected via USB3-WIRE (A) 3-WIRE (B) 2-WIREMeaning Illuminates with established USB connection Blinks during USB communicationIndicates that the supply voltage is present at the sensor connection Illuminates when there is no communication, pinsof sensor and supply connection are connected to each otherMODE LEDs indicate the current operating mode of the interface. This depends on the connectedsensor and is automatically adjusted by the software.Rear side:Characteristics The ECI-3 configuration interface enables connection of GHMHONSBERG sensors to the USB port of a computer.All sensors of the OMNI, FLEX, and LABO families, as well as other sensors which contain a microcontroller are supported.Both 2-wire and 3-wire sensors are supported.In combination with the 'HI-Tools' Windows software, it enables ● ● ● ●the modification of all the sensor's configuration settings the reading of measured valuesthe adjustment of inputs and outputs firmware updatesSENSOR SUPPLYTechnical data Auxiliary voltageSupply of the interface via USB 3-wire sensors also require a supply according to the sensor specifications inthe range of 10 – 30 V (Observe the sensor data sheet!)Connections Sensor Supply USB Operating temperature Storage temperature DimensionsHousing material Ingress protection Weight ConformityDevice socket M12x1, 5-pin Device connector M12x1, 5poleUSB jack type B 0..+50 °C -20..+80 °C 109 mm (W) x 67.5 mm (D) x 34 mm (H)AluminiumIP 40 0.16 kg (interface without accessories) 1.02 kg (case, incl. contents)CE20 pi-ho_zu-eci-3_e V1.00-01USBM12x1 socket, 5-pin for sensor connection M12x1 plug connector, 5-pin for supply lineconnection (only for 3-wire sensors) Pin 1 = +V Pin 3 = 0 V The assignment of the remaining pins depends onthe connected sensorUSB B-socket for connection to the USB port of the computerCommissioning The configuration interface is intended for temporary connection tothe application. Permanent installation in the system is not intended.The interface is initially connected to the USB port of the computer using the supplied USB cable. The power supply of the interfacetakes place via the USB port. Additional auxiliary voltage is not necessary at first. The drivers required for operation are providedon the supplied USB stick and are installed in the usual manner.Connection of the sensors takes place at the 'Sensor' port with the supplied M12x1 extension cable. The supplied adapter can be usedfor connection of sensors with a valve connector.No additional connections are necessary for operation with 2-wire sensors. The supply of sensors and interface takes place from theUSB port.1 ghm_pi-ho-sm-flow-rotor_probe_form_e V2.10-00
Technische Documenten
Prijs op aanvraag
Neem contact met ons op voor de beste prijs en snelle levering.