Rotterdam, Nederland | info@verkopershulp.nl English
Levering
Snelle levering in NL en BE
Kwaliteit
100% originele onderdelen
Support
Technisch advies beschikbaar
Senseca Meter

Senseca HD2102.2 Portable Luxmeter Data Logger

Op voorraad
|
Artikelnummer: HD2102.2

Specificaties

Merk
Senseca
Artikelnummer
HD2102.2
Categorie
Meter
Beschikbaarheid
Op voorraad

Productbeschrijving

Senseca products, including Senseca HD2102.2 Portable Luxmeter Data Logger, are sourced through parallel import channels and delivered to our customers worldwide with speed and reliability. Even if Senseca HD2102.2 Portable Luxmeter Data Logger is not listed on our website, you are welcome to request a price quote — our team will respond promptly with a tailored offer.TECHNICAL SPECIFICATIONS OF PROBES IN LINE WITH THE INSTRUMENT For the spectral response curves of the LP471… probes, see the probes datasheet available onthe Delta OHM website.LP471PHOT – Illuminance probe, with SICRAM module.Measurement range (lux) 0.10…199.99 …1999.9 …19999 …199.99x103 Resolution (lux)0.01 0.1 1 0.01x103 Spectral range in agreement with standard photopic curve V(λ)α (temperature coefficient) f6(T) <0.05% K Calibration uncertainty <4% <6%f'1 (in agreement with photopic response V(λ)) f2 (response according to cosine law)<3% f3 (linearity) <1% f4 (instrument reading error) <0.5% f5 (fatigue) <0.5%Class B Drift after 1 year <1% Operating temperature 0…50 °C Reference StandardCIE No. 69 – UNI 11142 LP471LUM2 - Luminance probe, with SICRAM module.Measurement range (cd/m2) 1…1999.9 …19999 …199.99x103 …1999.9x103 2 Resolution (cd/m )0.1 1 0.01x103 0.1x103 Optical angle 2° Spectral range in agreement with standard photopic curve V(λ)α (temperature coefficient) f6(T) <0.05% K Calibration uncertainty <5% <8%f'1 (in agreement with photopic response V(λ)) f3 (linearity) <1% f4 (instrument reading error)<0.5% f5 (fatigue) <0.5% Class C Drift after 1 year <1% Functioning temperature0…50°C Reference standardCIE no.69 LP471PAR / LP471PAR02 - Quantum radiometric probe for the measurement of the photon flowin the PAR chlorophyll range, with SICRAM module.0.1… 199.99 200.0…1999.9 2000…10000 Measurement range (µmol/m2s) 2 0.01 0.11 Resolution (µmol/m s) Spectral range 400 nm…700 nm Calibration uncertainty<5% f2 (response according to cosine law) <6% f3 (linearity) <1% f4 (instrument reading error)±1digit f5 (fatigue) <0.5% Drift after 1 year <1% Working temperature 0…50°CHD2102- 29 -V2.5

DATASENSECALUXMETERLUXMETER DATAHD2102.2 PORTABLE LUXMETERHD2102.2 PORTABLE LUXMETER DATAHD2102.2 PORTABLE LUXMETER DATA LOGGER

Prijs op aanvraag

Neem contact met ons op voor de beste prijs en snelle levering.

Vergelijkbare Producten